Customization: | Available |
---|---|
After-sales Service: | Free System Design |
Warranty: | 10-25 Years (Vary From Component to Part) |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Rated power of solar system | 120kW | 140kW | 160kW | 180kW | 200kW |
Recommend solar panel power | 144kW | 168kW | 192kW | 216kW | 240kW |
Minimum land area | 720m² | 840m² | 950m² | 1070m² | 1200m² |
Mounting structure | On metal roofs / tile roofs / concrete roofs / on ground (customized) | ||||
On grid solar inverter | 120kW | 140kW | 160kW | 180kW | 200kW |
Connected grid | 400V / 10kV / other | ||||
PV Cable (black / red) | 800m-1400m | ||||
Connector (MC4 compatible) | 40-60 pairs (FREE of charge) | ||||
Installation Toolkit | 5 sets (FREE of charge) |
[System Components]
1.Solar panel
-Regular solar panel or flexible solar panel
-Power range: 375W, 430W, 450W, 550W
-Warranty: 25 years
-0~+5W positive power tolerance
-PID Resistant, high salt and ammonia resistance
-Withstands 5400Pa snow and 2400Pa wind loads
-Compatible with 1500V system voltage.
2.Mounting structure
-Strictly machnical tested for wind & snow
-Pre-assembled packing for quick & easy installation
-Anodized aluminum & stainless steel material with high durability
-Angle adjustable opional
-Multiple solutions to fit for all kinds of roof situation
3.On-grid solar inverter
-Max. efficiency 98.7%
-Multi MPPTs for different input strings
-String current up to 25A
-Supports export power control, 485, WiFi, GPRS
-Certificte: G98 or G99, VDE-AR-N 4105 / VDE V 0124, EN 50549-1, VDE 0126 / UTE C 15 / VFR:2019, RD 1699 / RD 244 / UNE 206006 / UNE 206007-1, CEI 0-21, C10/11, NRS 097-2-1, TOR, EIFS 2018.2, IEC 62116, IEC 61727, IEC 60068, IEC 61683, EN 50530
-with warranty up to 10-year
On-grid Inverter fully considers the needs of end customers. While having excellent performance, it uses LEDs as inverter status displays to effectively improve product life. Using DSP digital control, it can withstand a wide range of grid voltage and has all-round protection functions; while maximizing the benefits, it greatly improves the reliability of the product.
4.DC Cable & MC4 Connector & Tools
There are several steps involved in packing and shipping a solar system, including:
Last but not least, the installation of the solar power system needs to be done precisely so that the maximum power can be generated through the solar power plant. No two roofs or grounds are the same, so the process requires system design and careful oversight to ensure the correct installation of a solar rooftop power plant.
In India, solar panels should be tilted at an angle between 8 and 33 degrees, but it varies depending on the installation height.
Solar panels must be grouted with anchor bolts or a concrete foundation to ensure durability in harsh conditions. The UPS and batteries must be mounted as close as possible to the panel to minimize DC transmission losses. When connecting panels in series it is necessary to ensure that the maximum allowable voltage is not exceeded.
There should be a minimum gap of 5 mm between two solar panels to allow for expansion of the material. Interconnected solar panels must be of the same type (monocrystalline or polycrystalline) and of the same power class. There should be no shadows on the solar panel as this can cause losses, hot spots etc.